Solax Power – Inverters – X3 Series

0,00 

https://www.solaxpower.com/

X3-MGA-50K-G2:
Max. PV array input power [kWp] – 75
No. of MPP trackers – 5
Rated AC output power [kW] – 50
Rated AC output current [A] – 75.8 / 72.5
THDi (Rated power) [%] – <3
Max. Efficiency [%] – 98.4
Euro. Efficiency [%] – 98.1

Datasheet – SOLAX X3-MGA-50K-G2

X3-PRO 30K G2

Max. recommended PV array power :45.0 kWp
Max. PV input voltage: 1100 V
Rated PV input voltage: 650 V
Max. input current per MPPT: 32 A
Rated output power: 30 kW
Rated output current: 45.5 A
Max. efficiency: 98.5%
European efficiency: 98%

solax-x3-pro-g2-datasheet-en

X3-PRO 20K G2

Max. recommended PV array power: 30.0 kWp
Max. PV input voltage: 1100 V
Rated PV input voltage: 650 V
Max. input current per MPPT: 32 A
Rated output power: 20 kW
Rated output current: 45.5 A
Max. efficiency: 98.5%
European efficiency: 98%

X3-AELIO-50K
Max. recommended PV array power: 100 kWp
Max. PV input voltage 1000 V
Nominal PV input voltage 650 V
MPPT voltage range 160 ~ 950 V
Start-up voltage 200 V
Number of MPP trackers/rows per tracker 5/2
Max. current per MPPT 40 A

X3H-ULTRA-15K
Max.recommended PV array power (Wp) 30000
Max.input DC power (W) 30000
Max.DC voltage (V) 1000
Nominal DC operating voltage (V) 600

X3H-ULTRA-19.9K
Max.recommended PV array power (Wp) 40000
Max.input DC power (W) 40000
Max.DC voltage (V) 1000
Nominal DC operating voltage (V) 600

X3H – ULTRA – 20K
Max.recommended PV array power (Wp) 40000
Max.input DC power (W) 40000
Max.DC voltage (V) 1000
Nominal DC operating voltage (V) 600

X3H – ULTRA – 25K
Max.recommended PV array power (Wp) 50000
Max.input DC power (W) 50000
Max.DC voltage (V) 1000
Nominal DC operating voltage (V) 600

X3H – ULTRA – 30K
Max.recommended PV array power (Wp) 60000
Max.input DC power (W) 60000
Max.DC voltage (V) 1000
Nominal DC operating voltage (V) 600

X3-AELIO-60K
Max. recommended PV array power(kW): 60
Max. PV input voltage(V): 1000
Rated PV input voltage(V): 650
MPPT voltage range(V): 160-950

Out of stock

SKU: 09502 Category:

Description

https://www.solaxpower.com/

X3-MGA-50K-G2:
Max. PV array input power [kWp] – 75
No. of MPP trackers – 5
Rated AC output power [kW] – 50
Rated AC output current [A] – 75.8 / 72.5
THDi (Rated power) [%] – <3
Max. Efficiency [%] – 98.4
Euro. Efficiency [%] – 98.1

Datasheet – SOLAX X3-MGA-50K-G2

X3-PRO 30K G2
Max. recommended PV array power :45.0 kWp
Max. PV input voltage: 1100 V
Rated PV input voltage: 650 V
Max. input current per MPPT: 32 A
Rated output power: 30 kW
Rated output current: 45.5 A
Max. efficiency: 98.5%
European efficiency: 98%

solax-x3-pro-g2-datasheet-en

X3-PRO 20K G2
Max. recommended PV array power: 30.0 kWp
Max. PV input voltage: 1100 V
Rated PV input voltage: 650 V
Max. input current per MPPT: 32 A
Rated output power: 20 kW
Rated output current: 45.5 A
Max. efficiency: 98.5%
European efficiency: 98%

X3-AELIO-50K
Max. recommended PV array power: 100 kWp
Max. PV input voltage 1000 V
Nominal PV input voltage 650 V
MPPT voltage range 160 ~ 950 V
Start-up voltage 200 V
Number of MPP trackers/rows per tracker 5/2
Max. current per MPPT 40 A

X3H-ULTRA-15K
Max.recommended PV array power (Wp) 30000
Max.input DC power (W) 30000
Max.DC voltage (V) 1000
Nominal DC operating voltage (V) 600

X3H-ULTRA-19.9K
Max.recommended PV array power (Wp) 40000
Max.input DC power (W) 40000
Max.DC voltage (V) 1000
Nominal DC operating voltage (V) 600

X3H – ULTRA – 20K
Max.recommended PV array power (Wp) 40000
Max.input DC power (W) 40000
Max.DC voltage (V) 1000
Nominal DC operating voltage (V) 600

X3H – ULTRA – 25K
Max.recommended PV array power (Wp) 50000
Max.input DC power (W) 50000
Max.DC voltage (V) 1000
Nominal DC operating voltage (V) 600

X3H – ULTRA – 30K
Max.recommended PV array power (Wp) 60000
Max.input DC power (W) 60000
Max.DC voltage (V) 1000
Nominal DC operating voltage (V) 600

X3-AELIO-60K
Max. recommended PV array power(kW): 60
Max. PV input voltage(V): 1000
Rated PV input voltage(V): 650
MPPT voltage range(V): 160-950

X3-NEO-15K-LV

Max. recommended PV array power – 30 kWp
Max. PV input voltage – 1000 V
Rated PV input voltage – 640 V
PV operating voltage range – 160–950 V
Dimensions – 520 × 705 × 258 mm
Weight – 45.2 kg

X3-NEO-20K-LV

Max. recommended PV array power – 40 kWp
Max. PV input voltage – 1000 V
Rated PV input voltage – 640 V
PV operating voltage range – 160–950 V
Start-up voltage – 150 V
Dimensions – 520 × 705 × 258 mm
Weight – 45.2 kg

Additional information