Description
Ress-1000-2090
AC parameters (in the network)
Rated power (charge/discharge) 1000 kW
Rated mains voltage 3W+N+PE,400V
Allowable range of mains voltage -10%~+15%
Rated mains frequency 50 Hz
Allowable range of mains frequency ±0.5 Hz
Output harmonics ≤ 3% (at rated power)
Power factor range -0.9~+0.9
THD coefficient ≤5%.
AC parameters (without network)
Rated power (discharge) 1000 kW
Maximum output power (discharge) 1045 kVA
Rated output voltage 3W+N+PE, 380/400V
Load asymmetry Up to 50%, short-term up to 100%
Voltage unbalance 2%, should not exceed 4% for a short time
Voltage change during transients ≤10%.
Rated frequency 50Hz
Resistance to temporary overload 1104 kW
Switching time to off-grid mode* ≤20 ms
Battery parameters
Cell chemistry Lithium iron phosphate
Cell manufacturer and brand CATL, 314Ah
Capacity of one battery pack 52.25 kWh
Number of battery assemblies 52
Capacity of the whole system 2089.984 kWh
Maximum charge/discharge rate 2 hours (duration may vary depending on
on the number of battery packs)
Battery life cycle 8,000 cycles (0.5C @ 25°C charge and discharge @ 90% DOD,
EOL 70%)
RESS1000-2150/2177
AC parameters (in the network)
Rated power (charge/discharge) 1000 kW
Rated mains voltage 3W+N+PE,400V
Allowable range of mains voltage -10%~+15%
Rated mains frequency 50 Hz
Allowable range of mains frequency ±0.5 Hz
Output harmonics ≤ 3% (at rated power)
Power factor range -0.9~+0.9
THD coefficient ≤5%.
AC parameters (without network)
Rated power (discharge) 1000 kW
Maximum output power (discharge) 1045 kVA
Rated output voltage 3W+N+PE, 380/400V
Load asymmetry Up to 50%, short-term up to 100%
Voltage unbalance 2%, should not exceed 4% for a short time
Voltage change during transients ≤10%.
Rated frequency 50Hz
Resistance to temporary overload 1104 kW
Switching time to off-grid mode* ≤20 ms
Battery parameters
Cell chemistry Lithium iron phosphate
Cell manufacturer and brand CATL, 314Ah
Capacity of one battery pack 52.25 kWh
Number of battery assemblies 52
Capacity of the whole system 2089.984 kWh
Maximum charge/discharge rate 2 hours (duration may vary depending on
on the number of battery packs)
Battery life cycle 8,000 cycles (0.5C @ 25°C charge and discharge @ 90% DOD,
EOL 70%)
RESS 100-215/242
AC parameters (in the network)
Rated power (charge/discharge) 115 kW
Rated mains voltage 3W+N+PE,400V
Allowable range of mains voltage -20%~+15%
Rated mains frequency 50 Hz
Allowable range of mains frequency ±2Hz
Output harmonics ≤ 3% (at rated power)
Power factor range -1~+1
THD coefficient ≤3%.
AC parameters (without network)
Rated power (discharge) 115 kW
Maximum output power (discharge) 126,5 kW
Load asymmetry Up to 50%, short-term up to 100%
Voltage unbalance 2%, should not exceed 4% for a short time
Voltage change during transients ≤10%.
Rated frequency 50Hz
Resistance to temporary overload 1104 kW
Switching time to off-grid mode* ≤20 ms
Battery parameters
Cell chemistry Lithium iron phosphate
Cell manufacturer and brand CATL, 314Ah
Capacity of one battery pack 46.592 kW/h
Number of battery assemblies 5
Capacity of the whole system 232.96 kW/h
Maximum charge/discharge rate 2 hours (duration may vary depending on
on the number of battery packs)
Battery life cycle 8,000 cycles (0.5C @ 25°C charge and discharge @ 90% DOD,
EOL 70%)