DALGAKIRAN – Diesel Generator – DJ Series

0,00 

Dalgakiran DJ 1100 BD
Model 12M26G1100/5
The number of cylinders is 12
The location of the V cylinders is similar
Volume l 31.8
Piston stroke mm 150
The diameter of the cylinder is 150 mm
The compression ratio is 15.7:1
Aspiration TURBOCHARGED AND INTERCOOLED
Electronic regulator
Cooling system Liquid
The volume of the OR is 148 l
Lubricant volume l 109
Electrical system Volt 24
Speed / Frequency 50 Hz RPM 1500 rpm/ 50 Hz
Full motor power (Standby 50 Hz) 973 kV
Fuel consumption at navant. %110 ESP 50 Hz l/h 227.4
Fuel consumption at navant. %100 PRP 50 Hz l/h 205.2

DJ169BD
The number of cylinders is 6
The arrangement of the cylinders is in-line
Volume l 6.75
Piston stroke mm 130
The diameter of the cylinder is 105 mm
The compression ratio is 18:1
Aspiration TURBOCHARGED AND AFTERCOOLED
Electronic regulator
Cooling system Liquid
The volume of the OR is 20 l
Lubricant volume l 17
Electrical system Volt 24
Speed / Frequency 50 Hz RPM 1500 rpm/ 50 Hz

DJ275BD
Maximum power, kW 220
Nominal power, kW 200
Alternator type Synchronous
Number of phases Three-phase
Voltage 230/400 V
Frequency 50 Hz
Output 12 V

DJ 290 BD
Voltage: 380
Frequency(Hz): 50
Power(kW): 230
Alternator type Synchronous
Number of phases Three-phase

DJ72BD
Voltage: 230/400
Frequency(Hz): 50
Power(kW): 52
Alternator type Synchronous
Number of phases Three-phase

DJ
220BD
Voltage: 230/400
Frequency(Hz): 50
Power(kW): 160
Alternator type Synchronous
Number of phases Three-phase

DJ 176
Voltage: 230/400
Frequency(Hz): 50
Power(kW): 176
Alternator type Synchronous

DJ87BD
Voltage: 230/400
Frequency(Hz): 50
Power(kW): 70

DJ108BD
Reserve power(kVA/kW): 108/86
Nominal power(kVA/kW): 98/78
Voltage: 230/400
Frequency(Hz): 50

DJ 50BD
Reserve power(kVA/kW): 50/40
Nominal power(kVA/kW): 45/36
Voltage: 230/400
Frequency(Hz): 50

DJ 125BD
Reserve power(kVA/kW): 125/100
Nominal power(kVA/kW): 113/90
Voltage: 230/400
Frequency(Hz): 50

DJ111BD
Reserve power(kVA/kW): 111/89
Nominal power(kVA/kW): 100/80
Voltage: 230/400
Frequency(Hz): 50

DJ715BD
Reserve power(kVA/kW): 715/572
Nominal power(kVA/kW): 650/520
Voltage: 230/400
Frequency(Hz): 50

DJ35BD
Max. power(kVA/kW): 44/35
Voltage(V): 230/400
Frequency(Hz): 50

DJ350BD
Max.Power(kW): 280
Voltage(V): 230/400
Frequency(Hz): 50

DJ69BD
Max.Power(kVA/kW): 69/55.2
Voltage(V): 400/230
Frequency(Hz): 50

DJ220CU
Max.Power(kVA/kW): 220/176
Voltage(V): 400/230
Frequency(Hz): 50

DJ45BD
Max.Power(kVA/kW): 45/40
Voltage(V): 400/230
Frequency(Hz): 50
DJ43BD
Max.Power(kVA/kW): 43/39
Voltage(V): 400/230
Frequency(Hz): 50

DJ85BD
Max.Power(kVA/kW): 85/68
Voltage(V): 400/230
Frequency(Hz): 50
DJ253BD
Max.Power(kVA/kW): 253/202
Voltage(V): 400/230
Frequency(Hz): 50

Out of stock

SKU: 08333 Category:

Description

DJ 1100 BD
Model 12M26G1100/5
The number of cylinders is 12
The location of the V cylinders is similar
Volume l 31.8
Piston stroke mm 150
The diameter of the cylinder is 150 mm
The compression ratio is 15.7:1
Aspiration TURBOCHARGED AND INTERCOOLED
Electronic regulator
Cooling system Liquid
The volume of the OR is 148 l
Lubricant volume l 109
Electrical system Volt 24
Speed / Frequency 50 Hz RPM 1500 rpm/ 50 Hz
Full motor power (Standby 50 Hz) 973 kV
Fuel consumption at navant. %110 ESP 50 Hz l/h 227.4
Fuel consumption at navant. %100 PRP 50 Hz l/h 205.2

DJ169BD
The number of cylinders is 6
The arrangement of the cylinders is in-line
Volume l 6.75
Piston stroke mm 130
The diameter of the cylinder is 105 mm
The compression ratio is 18:1
Aspiration TURBOCHARGED AND AFTERCOOLED
Electronic regulator
Cooling system Liquid
The volume of the OR is 20 l
Lubricant volume l 17
Electrical system Volt 24
Speed / Frequency 50 Hz RPM 1500 rpm/ 50 Hz

DJ275BD
Maximum power, kW 220
Nominal power, kW 200
Alternator type Synchronous
Number of phases Three-phase
Voltage 230/400 V
Frequency 50 Hz
Output 12 V

DJ 290 BD
Voltage: 380
Frequency(Hz): 50
Power(kW): 230
Alternator type Synchronous
Number of phases Three-phase

DJ72BD
Voltage: 230/400
Frequency(Hz): 50
Power(kW): 52
Alternator type Synchronous
Number of phases Three-phase

DJ
220BD
Voltage: 230/400
Frequency(Hz): 50
Power(kW): 160
Alternator type Synchronous
Number of phases Three-phase

DJ 176
Voltage: 230/400
Frequency(Hz): 50
Power(kW): 176
Alternator type Synchronous

DJ87BD
Voltage: 230/400
Frequency(Hz): 50
Power(kW): 70

DJ108BD
Reserve power(kVA/kW): 108/86
Nominal power(kVA/kW): 98/78
Voltage: 230/400
Frequency(Hz): 50

DJ 50BD
Reserve power(kVA/kW): 50/40
Nominal power(kVA/kW): 45/36
Voltage: 230/400
Frequency(Hz): 50

DJ 125BD
Reserve power(kVA/kW): 125/100
Nominal power(kVA/kW): 113/90
Voltage: 230/400
Frequency(Hz): 50

DJ111BD
Reserve power(kVA/kW): 111/89
Nominal power(kVA/kW): 100/80
Voltage: 230/400
Frequency(Hz): 50

DJ715BD
Reserve power(kVA/kW): 715/572
Nominal power(kVA/kW): 650/520
Voltage: 230/400
Frequency(Hz): 50

DJ35BD
Max. power(kVA/kW): 44/35
Voltage(V): 230/400
Frequency(Hz): 50

DJ350BD
Max.Power(kW): 280
Voltage(V): 230/400
Frequency(Hz): 50

DJ69BD
Max.Power(kVA/kW): 69/55.2
Voltage(V): 400/230
Frequency(Hz): 50

DJ220CU
Max.Power(kVA/kW): 220/176
Voltage(V): 400/230
Frequency(Hz): 50

DJ45BD
Max.Power(kVA/kW): 45/40
Voltage(V): 400/230
Frequency(Hz): 50

DJ43BD
Max.Power(kVA/kW): 43/39
Voltage(V): 400/230
Frequency(Hz): 50

DJ85BD
Max.Power(kVA/kW): 85/68
Voltage(V): 400/230
Frequency(Hz): 50

DJ253BD

Max.Power(kVA/kW): 253/202
Voltage(V): 400/230
Frequency(Hz): 50

Additional information

Producer

Type

,