Alvog IT – Cogeneration Unit – TCG

0,00 

Gas engine genset(s) 1 x TCG 2020 V12:
Combustion gas Natural gas
Methane number 80
Lower heat value kWh/Nm³ 10.18
Gas density kg/Nm³ 0.79
Electrical terminal power at cos φ = 1.000 /
ind./overexcited
kW 1200
Cooling water heat (± 8%) kW 609
NT mixture cooler heat (± 8%) kW 107
Exhaust gas recooling temperature °C 120
Exhaust gas heat at recooling temperature (± 8%) kW 580
Fuel use (+ 5%) kW 2749
Electrical efficiency % 43.7
Thermal efficiency % 43.3
Total efficiency % 87.0

Out of stock

SKU: 10252 Category:

Description

Gas engine genset(s) 1 x TCG 2020 V12:
Combustion gas Natural gas
Methane number 80
Lower heat value kWh/Nm³ 10.18
Gas density kg/Nm³ 0.79
Electrical terminal power at cos φ = 1.000 /
ind./overexcited
kW 1200
Cooling water heat (± 8%) kW 609
NT mixture cooler heat (± 8%) kW 107
Exhaust gas recooling temperature °C 120
Exhaust gas heat at recooling temperature (± 8%) kW 580
Fuel use (+ 5%) kW 2749
Electrical efficiency % 43.7
Thermal efficiency % 43.3
Total efficiency % 87.0